Issued Patents All Time
Showing 101–125 of 171 patents
| Patent # | Title | Co-Inventors | Date |
|---|---|---|---|
| 7272945 | Environmental condition measurement system | George Forman, Chandrakant Patel | 2007-09-25 |
| 7269751 | Supplying power to at least one electrical device based on an efficient operating point of a power supply | Gopalakrishnan Janakiraman, Keith Farkas, Chandrakant Patel | 2007-09-11 |
| 7251547 | Correlation of vent tile settings and rack temperatures | Chandrakant Patel, Ratnesh Sharma, Abdlmonem Beitelmal | 2007-07-31 |
| 7248942 | Airflow detection system having an airflow indicating device | George Forman, Ratnesh Sharma | 2007-07-24 |
| 7240500 | Dynamic fluid sprayjet delivery system | Chandrakant Patel, Ratnesh Sharma | 2007-07-10 |
| 7236896 | Load management in a power system | Keith Farkas, Parthasarathy Ranganathan | 2007-06-26 |
| 7218996 | Method for thermally managing a room | Abdlmonem Beitelmal, Chandrakant Patel | 2007-05-15 |
| 7203063 | Small form factor liquid loop cooling system | Glenn C. Simon, Christopher G. Malone, Ratnesh Sharma | 2007-04-10 |
| 7197433 | Workload placement among data centers based on thermal efficiency | Chandrakant Patel, Ratnesh Sharma, Sven Graupner | 2007-03-27 |
| 7194337 | Agent-based operation of a robotic device | Ratnesh Sharma, Chandrakant Patel | 2007-03-20 |
| 7170745 | Electronics rack having an angled panel | Martin Arlitt, Ratnesh Sharma | 2007-01-30 |
| 7155318 | Air conditioning unit control to reduce moisture varying operations | Ratnesh Sharma, Chandrakant Patel | 2006-12-26 |
| 7134289 | Multi-state spray cooling system | Chandrakant Patel, Ratnesh Sharma | 2006-11-14 |
| 7114555 | Controlled cooling of a data center | Chandrakant Patel, Ratnesh Sharma, Abdlmonem Beitelmal | 2006-10-03 |
| 7117129 | Commissioning of sensors | Chandrakant Patel, Ratnesh Sharma | 2006-10-03 |
| 7086603 | Data collection system having a data collector | David A. Moore, Chandrakant Patel | 2006-08-08 |
| 7082778 | Self-contained spray cooling module | Chandrakant Patel | 2006-08-01 |
| 7072739 | Data center robotic device | Abdlmonem Beitelmal, Keith Farkas, Chandrakant Patel, Parthasarathy Ranganathan | 2006-07-04 |
| 7068508 | Docking station cooling system including liquid-filled hollow structure | Chandrakant Patel | 2006-06-27 |
| 7068509 | Small form factor cooling system | Glenn C. Simon, Christopher G. Malone | 2006-06-27 |
| 7057506 | Cooling fluid provisioning with location aware sensors | Salil Pradhan, Chandrakant Patel | 2006-06-06 |
| 7051946 | Air re-circulation index | Ratnesh Sharma, Chandrakant Patel | 2006-05-30 |
| 7031870 | Data center evaluation using an air re-circulation index | Ratnesh Sharma, Chandrakant Patel | 2006-04-18 |
| 7031802 | Semi-autonomous operation of a robotic device | Chandrakant Patel, Ratnesh Sharma | 2006-04-18 |
| 7031154 | Louvered rack | Ratnesh Sharma | 2006-04-18 |