| Patent # | Title | Co-Inventors | Date |
|---|---|---|---|
| 11665861 | Edge datacenter nano enclosure with chimney and return air containment plenum | Mark M. Bailey | 2023-05-30 |
| 11606883 | Method for backflow prevention in an airflow plenum of a modular data center | Mark M. Bailey, Ty Schmitt | 2023-03-14 |
| 11602082 | Data center that regulates air pressure within an interior compartment | Mark M. Bailey | 2023-03-07 |
| 11523536 | Rack mounted equipment with rear post mounted air filter panels | Gerald Courtney, Anthony Middleton | 2022-12-06 |
| 11513572 | Systems and methods for automated startup and bypass at an edge datacenter | Mark M. Bailey, Colin Mahaffey, Tyler B. Duncan | 2022-11-29 |
| 11357134 | Data center cooling system that selectively delays compressor restart of a mechanical cooling system | Tyler B. Duncan | 2022-06-07 |
| 11277943 | Modular data center having an air cooled external equipment panel | Mark M. Bailey, Tyler B. Duncan, James Davis | 2022-03-15 |
| 11234345 | Data center having a differential pressure relief mechanism between cold and hot aisles | Anthony Middleton, Tyler B. Duncan | 2022-01-25 |
| 11039551 | Data center that regulates supply air to multiple compartments | Mark M. Bailey, Ty Schmitt | 2021-06-15 |
| 11006551 | Method for re-direction of airflow from air handler system(s) integrated into a modular data center | Mark M. Bailey | 2021-05-11 |
| 10925185 | Modular data center with integrated return air plenum for external side-mounted air cooling unit | Mark M. Bailey | 2021-02-16 |
| 10856449 | Dynamic cooling system | Mark M. Bailey, Tyler B. Duncan, Ty Schmitt | 2020-12-01 |
| 10837684 | Automatic controls method for adding the optimal amount of refrigerant to a direct expansion cooling system | Michael Mitsuo Toulouse, Tyler B. Duncan | 2020-11-17 |
| 10820451 | Multimode cooling control of air handling units to prevent condensation | Tyler B. Duncan, Michael Mitsuo Toulouse, Ty Schmitt | 2020-10-27 |
| 10772241 | Closed-loop supplemental heater system in an air handler system of outside air cooled data center | Mark M. Bailey, Tyler B. Duncan, Michael Mitsuo Toulouse | 2020-09-08 |
| 10736231 | Modular data center with passively-cooled utility module | Mark M. Bailey, Tyler B. Duncan, Ty Schmitt | 2020-08-04 |
| 10674638 | Fail-on cooling system | Mark M. Bailey, Tyler B. Duncan | 2020-06-02 |
| 10433466 | Mixing chamber for air handling in an information handling system | Mark M. Bailey, Tyler B. Duncan, Ty Schmitt | 2019-10-01 |
| 10356933 | Modular data center with utility module | Mark M. Bailey, Ty Schmitt | 2019-07-16 |
| 10178794 | Flexible utility room configuration with interchangeable interface panel | Mark M. Bailey, Tyler B. Duncan, Ty Schmitt, Anthony Middleton | 2019-01-08 |
| 10058013 | Environment-controlled cooling mode selection for a modular data center based on detection of contaminants and particulates in outside air | Ty Schmitt, Mark M. Bailey, Tyler B. Duncan | 2018-08-21 |